Click to enlarge photo
- Ballastless, Compact Lightweight, Air
cooled, Precise regulation
- Potted high-voltage sections
- Negative output
- Open frame or enclosed designs
- Meets UL544 guidelines for leakage current
- Open and short circuit protected
- Remote analog output control
|
Output:
|
300 Watt, PX50
|
700 Watt, PX100
|
|
Footprint:
|
12.25"x6.75"x3"
(LWH)
312x172x76mm
|
13"x6.75'x5.25' (LWH)
330x172 x133mm
|
|
Weight:
|
4.2 lbs
|
11.2 lbs
|
|
HV Insulation:
|
HV assembly potted in
repairable RTV
|
|
Mounting Position:
|
Any
|
|
HV Output:
|
Dry cable well with 2 meter long cable
|
|
Interface Connector:
|
10 PIN Panduit
|
|
Mounting Hardware:
|
(4) 10-32 UNC inserts
|
|
Certification:
|

|
|
|
PX100-oem & PX50-oem
|
| Model |
Rated CW
Power |
Strike
Voltage |
Max
Continuous
Voltage |
|
PX-50-oem |
300 W
|
30 kV
|
25 kV
|
|
PX-100-oem |
700 W
|
50 kV
|
36 kV
|
| Model: |
PX50-oem
|
PX100-oem
|
|
Ignition Voltage: |
30kV |
50kV |
Maximum
Continuous
Voltage: |
25kV |
40kV |
Maximum
Available Current: |
1ma-@25
kV
10mA-@18-kV
15mA-@15-kV
25mA-@12-kV |
2mA-@-36
kV
12mA-@-28
kV
35mA-@-20
kV
40mA-@-12
kV |
|
Maximum Pulse Current: |
40mA |
60mA |
Maximum Steady
State Current: |
25mA |
35mA |
|
Maximum CW Power Output: |
300W |
700W |
|
Current Regulation: |
+ 1% of
F.S.
(1 to 25ma) |
+ 1% of
F.S.
(1 to 40mA) |
| Main
Switching Frequency: |
42kHz
|
|
Pulse Rep Rate: |
D.C. to 1kHz
|
|
Pulse Duty Cycle: |
0 to 100%
|
|
Input Voltage:
|
120 or 220 Vac +/- 10%, 50/60Hz (specify)
|
|
Input Current |
5 A / 2.5 A |
10 A / 6 A |
|
Metering Signal Current: |
0-5V=0-25mA |
0-10V=0-50mA |
|
Internal Setpoint Controls: |
NA |
One-turn
potentiometers |
|
Remote Setpoint Signals: |
Same as metering signals
|
|
Remote HV on Signal: |
5V @ 5mA into Opto-Isolator or Contact
Closure
|
|