Parallax Technology, Inc.

High voltage power supplies for co2 lasers
electrical and physical specifications
"PX100-oem same as UVC LRC-50-40N"



Click to enlarge photo Click to enlarge

  • Ballastless, Compact Lightweight, Air cooled, Precise regulation

  • Potted high-voltage sections

  • Negative output

  • Open frame or enclosed designs

  • Meets UL544 guidelines for leakage current

  • Open and short circuit protected

  • Remote analog output control


Output:
300 Watt, PX50
700 Watt, PX100
Footprint:
12.25"x6.75"x3"
(LWH)
312x172x76mm
13"x6.75'x5.25' (LWH)
330x172 x133mm
Weight:
4.2 lbs
11.2 lbs
HV Insulation:

HV assembly potted in
repairable RTV

Mounting Position:

 Any

HV Output:

Dry cable well with 2 meter long cable

Interface Connector:

10 PIN Panduit

Mounting Hardware:

(4) 10-32 UNC inserts

Certification:



 PX100-oem & PX50-oem
Model Rated CW
Power
Strike
Voltage
Max
Continuous
Voltage
PX-50-oem

300 W

30 kV

25 kV

PX-100-oem

700 W

50 kV

36 kV


Model: PX50-oem PX100-oem
Ignition Voltage: 30kV 50kV
Maximum
Continuous
Voltage:
25kV 40kV
Maximum
Available Current:
1ma-@25 kV
10mA
-@18-kV
15mA
-@15-kV
25mA
-@12-kV
2mA-@-36 kV
12mA
-@-28 kV
35mA
-@-20 kV
40mA
-@-12 kV
Maximum Pulse Current: 40mA 60mA
Maximum Steady
State Current:
25mA 35mA
Maximum CW Power Output: 300W 700W
Current Regulation: + 1% of F.S.
(1 to 25ma)
+ 1% of F.S.
(1 to 40mA)
Main Switching Frequency:
42kHz
Pulse Rep Rate:
D.C. to 1kHz
Pulse Duty Cycle:
0 to 100%
Input Voltage:
120 or 220 Vac +/- 10%, 50/60Hz (specify)
Input Current  5 A / 2.5 A 10 A / 6 A
Metering Signal Current:  0-5V=0-25mA 0-10V=0-50mA 
Internal Setpoint Controls:  NA One-turn potentiometers
Remote Setpoint Signals:
Same as metering signals
Remote HV on Signal:
5V @ 5mA into Opto-Isolator or Contact Closure
Table of Contents

Laser tube prices | Re-gas & other service prices | International prices | Pictures of lasers
Misc. surplus equipment | Frequently asked questions